These six parameters are the core of intrinsic safety calculations. Those with o are the output of the safety barrier (output), those with i are the input of the field device (input). There is only one matching principle:Output must not exceed input.
| Safety barrier side | Field device side | Relationship | Typical value (example) |
|---|---|---|---|
Uo Maximum output voltage |
Ui Maximum permissible input voltage |
Uo ≤ Ui |
28 V ≤ 30 V |
Io Maximum output current |
Ii Maximum permissible input current |
Io ≤ Ii |
93 mA ≤ 100 mA |
Po Maximum output power |
Pi Maximum permissible input power |
Po ≤ Pi |
0.65 W ≤ 0.75 W |
Co Permissible external capacitance |
Ci Internal device capacitance |
Ci + Cc ≤ Co |
5 nF + 60 nF ≤ 83 nF |
Lo Permissible external inductance |
Li Internal device inductance |
Li + Lc ≤ Lo |
0 + 2 mH ≤ 4 mH |
Note that Po is not a simple multiplication:Po calculated by the manufacturer according to the spark ignition curves specified in the standard, and is not equal to Uo × Io. Some sources refer to Po as Uo × Io an estimate, the resulting value is on the high side and may lead to a false judgement of "mismatch". When verifying, use the value marked on the nameplate or certificate as the Po reference.

How much margin to allow:There is no mandatory uniform value, but engineering practice is to allow a margin of 10% or more for voltage and current, and 15% or more for power. If the margin is too small, batch differences or temperature drift may flip the verification conclusion. If the margin is too large, it means an oversized barrier has been selected, which may waste cost.