Solenoid valves

ASCO solenoid valves and general solenoid valve principles, common model selection and application maintenance FAQs

80 questions in total. Click a title to expand the answer.

How should spare solenoid valves be stored?

Spare valves should be stored in a dry environment free of corrosive gases, away from direct sunlight and extreme temperatures; fit dust protection to the inlet and outlet to prevent ingress of contaminants; after long-term storage, install […]

What are the common signs of incorrect solenoid valve selection?

Typical symptoms: no action when energised (voltage mismatch or insufficient differential pressure), leakage due to incomplete closure (seal material incompatible with the medium or port size too large), insufficient flow (Kv too small […]

What should be noted when reassembling a solenoid valve after inspection?

During reassembly, follow the reverse of the disassembly sequence, observe the installation direction and position of the valve spool, spring and seals, and tighten threads to the specified torque (over-tightening will damage the seal or valve body); after reassembly […]

Which ASCO valve types are selected for air compressors/pneumatic systems?

Air compressors and pneumatic systems mainly use 3/2, 5/2 and 5/3 directional valves to control cylinders and switch air circuits, requiring fast response, resistance to contamination and long service life. Pilot-operated valves […]

How are ASCO solenoid valves selected for the water treatment industry?

For water treatment applications, select by medium (raw water/dosing/pure water): for acid and alkali dosing, choose a 316 stainless steel valve body + PTFE seal; for general water systems, use brass or […]

What are the features of the ASCO 560 and 562 series spool valves?

The 562 is an ASCO spool valve series (often grouped with the 551 in the pneumatic directional control valve family), used for directional control of air/inert gases, offering multi-port […]

How are the ASCO 353, 320 and 314 series distinguished and selected?

The 353, 320 and 314 are ASCO general-purpose solenoid valve series, differing mainly in port size, flow rate, function combinations and valve body material. During selection, first select according to the medium […]

Are solenoid valves and pneumatic solenoid valves the same category?

Solenoid valves are a broad category classified by drive method (solenoid coil); pneumatic solenoid valves (also called solenoid pilot-operated pneumatic valves) specifically refer to valves controlled by a solenoid pilot, with the main valve driven by compressed air […]

What harm do impurities in the medium cause to solenoid valves?

Impurities wear the valve spool and seat and jam the pilot orifice and throttle ports, causing the valve to leak, respond slowly or fail. Media containing particles should be fitted with a filter, and the valve should be cleaned periodically […]

How is the valve "function" written in the selection table?

The "function" in the selection table describes the number of ports and positions and the normally open/normally closed state of the valve, e.g. "two-way-2/2 […]

Where can I find the detailed specifications of a specific ASCO solenoid valve model?

Refer to the official ASCO datasheets and certification documents to verify function, port size, flow rate, pressure, materials, voltage and explosion protection rating. The product pages on this site compile A […]

How can the service life of a solenoid valve be extended?

Key measures: keep the medium clean (install a filter), avoid operation above rated pressure and temperature, select the correct voltage and duty cycle, avoid unnecessary frequent actuation, and periodically disassemble, inspect and service the seals […]

Can a protective cover be added when a solenoid valve's ingress protection rating is insufficient?

A protective cover or rain hood can be added to improve the external environment, but it cannot replace the product's own ingress protection rating, nor can it be used to change suitability for a hazardous area. For outdoor, washdown and similar applications […]

Can solenoid valves be mounted horizontally, or must they be mounted vertically?

Most solenoid valves can be mounted horizontally or vertically, but the coil is usually recommended to face upwards to aid heat dissipation and reduce the ingress of contaminants into the pilot section. The specific mounting orientation is subject to each product's manual […]

How do you troubleshoot unstable operation of a system comprising a solenoid valve and a cylinder?

Troubleshooting sequence: ① Is the air supply pressure stable and does it reach the minimum operating pressure differential; ② Is the pilot orifice/throttle port blocked; ③ Is exhaust unobstructed and is the silencer blocked; ④ Is the wiring […]

How is safety confirmed after servicing a gas solenoid valve?

After servicing a gas valve, a leak test (e.g. with soapy water or a dedicated leak detector) must be performed to confirm there is no leakage, and the de-energised shut-off function and manual reset must be verified as reliable. Gas systems […]

What should be noted when a solenoid valve is used in a vacuum system?

For vacuum applications, select a zero-pressure-start or vacuum-suitable solenoid valve; ordinary pilot-operated valves rely on a pressure differential and cannot open reliably under vacuum. Also pay attention to valve body sealing and medium flow direction […]

What should be done about water hammer when a solenoid valve operates?

Water hammer is the pressure surge generated when fluid is suddenly shut off by a valve, and it can damage piping and valves. Mitigation methods: use slow-closing solenoid valves, extend the closing time, install water […]

How can you tell whether a solenoid valve is normally open or normally closed?

Method: check the function code in the model/order number (e.g. 2/2 NC/NO), check the valve body marking, or perform a power-off air flow test — if air does not pass when de-energised, it is […]

Which consumes less power: a solenoid valve energised long-term or de-energised long-term?

A normally closed solenoid valve is normally de-energised (no power, no consumption) and is only energised at the moment of actuation, so it is the most energy-efficient; a normally open type is normally energised to stay open, continuously consuming power and generating heat. Because […]

Which parameters must be checked when replacing a solenoid valve coil?

Must check: voltage and AC/DC type, power (W/VA), frequency (50/60Hz), connection and mounting dimensions, explosion protection rating (if applicable), protection […]

What should be noted after servicing an explosion-proof solenoid valve?

After servicing, the integrity of the explosion-proof construction must be restored: clean the flameproof surfaces and apply anti-corrosion grease, tighten all bolts, ensure seals are intact, tighten the cable gland, and ensure reliable earthing of the enclosure. Inspect […]

Do the exhaust ports of solenoid valves (3/2, 5/2 valves) need silencers?

Yes. The compressed air discharged from the exhaust port generates noise; silencers are usually fitted to reduce noise and prevent dust from entering the valve. The exhaust port must not be blocked, otherwise spool movement is affected […]

What are the symptoms of a blocked pilot port in a pilot-operated solenoid valve?

Typical symptoms of a blocked pilot port: the main valve does not actuate or actuates slowly after energisation, the valve cannot open fully, and flow is insufficient. The cause is medium impurities entering the pilot port. The remedy is […]

How is a solenoid valve with manual reset used?

A manual reset valve must be reset by hand after power loss or tripping before it can reopen; it is used in safety interlock applications to prevent automatic recovery from a fault […]

Can solenoid valves freeze in severe winter? How can freezing be prevented?

Water or moisture freezing inside the valve can jam the spool or crack the valve body. Frost protection measures: install in a frost-protected environment, apply heat tracing and insulation, select low-temperature-resistant seals, and drain accumulated […]

Do solenoid valves require regular maintenance? What does maintenance involve?

Yes. Maintenance tasks: periodically dismantle and clean the spool and pilot port, check seals and elastomers for ageing, check coil insulation and wiring, verify actuation reliability, clean or replace […]

Is it normal for a solenoid valve coil to heat up?

The coil heats up when energised; a temperature rise within the permitted range is normal. However, if the temperature is too high or the coil even burns out, possible causes are: incorrect voltage (e.g. a DC coil connected to AC), prolonged […]

How should leakage (failure to close tightly) after a solenoid valve closes be handled?

Common causes of failure to close tightly: worn or aged seals, media impurities trapped in the valve port, damage to the valve spool/seat, spring failure. The remedy is to disassemble and inspect, clean the spool and seat, […]

How do I troubleshoot a solenoid valve that does not actuate after power is applied?

Check in sequence: ① whether the coil is energised (measure voltage with a multimeter); ② whether the coil is burnt out (measure resistance, open circuit means damaged); ③ whether the spool is stuck (media impurities or crystallisation […]

What should be noted when wiring a solenoid valve?

Before wiring, confirm the coil voltage matches the supply (AC/DC, voltage level), note the polarity of DC coils (most are non-polarised, but those with LED/surge protection may […]

How do I verify that the selected solenoid valve model is correct?

Finally confirm four things: ① media compatibility (valve body/seal); ② pressure and flow (including opening differential pressure) meet the operating conditions; ③ voltage, explosion protection and ingress protection rating match the site […]

How do I weigh imported versus domestic solenoid valves in selection?

Imported brands (such as ASCO) generally lead in reliability, service life, certification completeness and operating condition coverage, and suit critical circuits, hazardous areas and harsh media; domestic […]

Why does the same series have dozens of order numbers?

Within the same series, order numbers distinguish different port sizes, functions (normally open/normally closed), body materials, seal materials, connection sizes and coil voltage combinations, thus giving rise to a large […]

How do I determine the solenoid coil power and power supply capacity during selection?

Coil power is expressed in watts (DC) or volt-amperes (VA, AC); the inrush current of an AC coil may be several times the holding current. When designing the power supply and relay/solid-state relay […]

Do pilot-operated solenoid valves have requirements on media cleanliness?

Yes. The pilot orifice and throttle are small, and impurities in the media can easily block them, preventing the valve from opening or closing properly, so pilot valves generally require clean media, […]

How do I choose the "optional elastomer materials" for ASCO solenoid valves?

Elastomer materials (seals) are selected by media and temperature: NBR is commonly used for water/air; PTFE/EPDM for steam; NBR/FKM for oils; high […]

What information does an ASCO solenoid valve order number contain?

The order number usually encodes information such as series, function, body material, connection, coil voltage and options. For example, SC8327G041AC115-120 […]

How do I select an ASCO solenoid valve series according to the media?

General air/water/oil: 210, 316, 314 and other general-purpose series; steam/hot water: 220; gas: 214, 040; corrosive media: select […]

What key parameters are needed to select a solenoid valve?

Core parameter checklist: ① media type and compatibility; ② function (2/2, 3/2, 5/2 and normally open/normally closed); ③ port size and flow (Kv/Cv); […]

How do ASCO timers pair with solenoid valves?

ASCO offers solenoid valve timers (including versions with power cable and with DIN connector), which automatically switch the solenoid valve on/off at set times, used for timed purging […]

What are ASCO RB, K29684 and K29708 miniature valves suitable for?

The RB series are miniature valves; K29684 and K29708 are manifold-mounted miniature solenoid valves, compact and suitable for space-constrained precision equipment […]

What is special about ASCO NP8262/NP8263 nuclear-grade solenoid valves?

NP8262 and NP8263 are Nuclear Qualified solenoid valves, meeting the nuclear industry's requirements for reliability, seismic […]

What are ASCO Numatics Mark series directional control valves?

Numatics is ASCO's pneumatic valve brand; the Mark 3, Mark 8, Mark 15 and Mark 40 series […]

What advantages do ASCO X210 and X223 electronically enhanced solenoid valves offer?

X210 and X223 are electronically enhanced solenoid valves. X223 is 2/2 […]

What are the benefits of built-in surge protection in the ASCO 2WSNF solenoid head?

The 2WSNF solenoid head has built-in surge protection, meeting lightning surge protection requirements without separately designing, purchasing or installing electrical connection components, with a small footprint and […]

What are the differences between ASCO explosion-proof solenoid valves (2WSNF, LPKF, WBLP)?

These are explosion-proof solenoid heads/valves for hazardous areas: 2WSNF is an explosion-proof solenoid head with integrated lightning surge protection (can be fitted to 327/551/553 […]

What pressure is the ASCO 223 high-pressure solenoid valve suitable for?

The 223 is a high-pressure solenoid valve for on/off control of high-pressure liquids or gases, with body and seals designed for high-pressure conditions. For specific rated pressure, port size and connection, refer to the official data […]

What are the differences between the ASCO 231, 221 and 220 series?

231, 221 and 220 each have their own focus: 220 is a steam and hot water valve (floating PTFE diaphragm, high flow); 221 is a slow-closing solenoid valve […]

What types are the ASCO 316, 362, 562, 353, 320 and 314 series?

These are ASCO's general-purpose solenoid valve/spool valve series: 316, 314, 320 and 353 are mostly general-purpose solenoid valves, while 362 and 562 are spool […]

What applications is the ASCO 342 series spool valve suitable for?

The 342-S is a high-flow single-coil or dual-coil spool valve; its direct-acting and high-flow construction makes it particularly suitable for analytical and diagnostic equipment, biofuels, dust collector systems, heating equip […]

What applications is the ASCO 040 series gas shut-off valve suitable for?

The 040 series is a gas shut-off valve suitable for on/off gas control of small gas burners and gas equipment, often as part of a safety shut-off or combustion control system. Selection […]

Where is the ASCO 214 series gas shut-off valve used?

The 214 (8214) is a high-flow, low-pressure (5 psi) gas safety shut-off valve designed specifically for on/off gas control of commercial and industrial gas burners. Dual valve discs […]

Why is the ASCO 220 series suitable for steam and hot water?

The 220 series is designed specifically for steam and hot water, with flow rates up to 60% higher than comparable products (the flow of a 3/4″ valve is equivalent to a competitor's 1&# […]

What are the features of the ASCO 551 (8551) series spool valve?

The 551 (8551) is a 1/4″ three-way and four-way compact solenoid valve for controlling air or inert gas. The unique T-shaped seal […]

Why is the ASCO 327 (8327) series suitable as a pilot valve?

The 327 (8327) is a two-position three-way direct-acting solenoid valve; its balanced poppet construction enables zero-pressure operation and low-power actuation of high flows; the PTFE guide ring and graphite pack […]

What operating conditions is the ASCO 210 (8210) series suitable for?

The ASCO 210 (also known as 8210) is a high-flow general-purpose solenoid valve suitable for liquids, corrosive media and air/inert gas, offering a wide range […]

What is the ”fail-safe” design of a solenoid valve?

Fail-safe means that when the system loses power or the control signal is interrupted, the valve automatically returns to a safe position (e.g. closing the gas supply, opening a relief). A normally closed solenoid valve closes on power loss, which is the most […]

Can the solenoid head (coil) be replaced separately?

Most solenoid valve coils (solenoid heads) are of removable design and can be replaced individually when damaged, without replacing the entire valve body. When replacing, verify the voltage, power, connection type and […]

What does the ”IP protection rating” of a solenoid valve mean?

The IP protection rating indicates the enclosure's protection against solid foreign objects (first digit) and water (second digit); for example, IP65 means dust-tight and protected against water jets. For outdoor, washdown […]

Which media are solenoid valves suitable for?

Different series are suitable for different media: general-purpose types for air, water and oil; corrosion-resistant types for corrosive fluids such as acids and alkalis; steam types for saturated steam/hot water; gas types for […]

Are there requirements for the installation orientation of solenoid valves?

Most solenoid valves have certain installation orientation requirements, typically with the coil facing upwards, installed horizontally or vertically, to prevent impurity deposits from affecting spool movement. Valves with gravity drain or pilot exhaust […]

Can one coil control two valve positions simultaneously?

A single-coil valve can only actuate in one direction when energised and resets by spring; a double-coil valve (e.g. 5/2 double solenoid) has two coils controlling two directions respectively, and a pulse energisation […]

What influence do the medium temperature and ambient temperature have on solenoid valves?

The medium temperature affects the resistance of seals and valve body materials, while the ambient temperature affects coil heat dissipation and permissible energisation time. High-temperature media require high-temperature-resistant seals (e.g. PTFE […]

What is the Kv/Cv value of a solenoid valve?

Kv (or Cv) is the flow coefficient of a valve, indicating the valve's flow capacity at a specified differential pressure, used to select the valve size according to flow requirements. The larger the Kv, the greater the flow at the same differential pressure […]

Can solenoid valves operate frequently? What is their service life?

Industrial solenoid valves are typically designed for a positive service life of millions of cycles, with direct-acting types and high-quality seal designs lasting longer. In frequent-operation applications, attention must be paid to coil heat dissipation (long-term energisation […]

What is the response time of a solenoid valve?

Response time refers to the time required from coil energisation (or de-energisation) until the spool completes its movement and the fluid path is switched, typically from a few milliseconds to several hundred milliseconds. Direct-acting types are faster than pilot-operated types; […]

What are the similarities between the operating principle of a solenoid valve and a relay?

Both use the principle of an electromagnetic coil attracting when energised: a relay uses electrical contacts to switch a circuit, while a solenoid valve uses a spool to switch a fluid path. The difference is that a relay switches electrical signals […]

Why is the seal material of a solenoid valve important?

Seals (elastomer/diaphragm) are in direct contact with the medium; their material determines temperature resistance, corrosion resistance and service life. Common materials include NBR (nitrile, oil-resistant), PTFE (polytetra […]

What is "zero pressure differential start" of a pilot-operated solenoid valve?

A standard pilot valve relies on the medium's pressure differential to open the main valve and cannot open reliably when the inlet pressure is too low. "Zero pressure differential start" uses a special structure […]

What is the difference between a solenoid valve and a motorised valve?

Solenoid valves are driven by electromagnetic force, actuate quickly (milliseconds to seconds), suit frequent switching and are commonly used for on/off control and small bore sizes; motorised valves are driven by a motor, actuate slowly but offer precise […]

What is the relationship between ASCO and Shige?

ASCO is the abbreviation of American Scientific Company; its Chinese name is "Shige"&#82 […]

How should the body material of a solenoid valve be selected?

The body material determines corrosion resistance and suitable media: brass is economical and versatile, used for water, air and oil; 304/316 stainless steel is corrosion-resistant, used for corrosive media, […]

What are the common coil voltage specifications for solenoid valves?

Common DC voltages are 12 VDC and 24 VDC; AC voltages are 24 V, 110/120 V, 220/240 V (50/6 […]

What is the difference between direct-acting and pilot-operated solenoid valves?

Direct-acting: electromagnetic force lifts the valve spool directly, operates at zero pressure differential and responds quickly, but bore size and flow rate are limited. Pilot-operated: electromagnetic force first opens the pilot orifice, then the medium's pressure differential […]

How do you distinguish and select between normally closed and normally open solenoid valves?

Normally closed (NC): the valve port is closed and the medium does not flow when de-energised, and it opens only when energised — the most common type, preferred for fail-safe closed applications. Normally open (NO): when de-energised […]

Where are five-port (5/2, 5/3) solenoid valves used?

Five-port valves have five ports (1 inlet, 2/4 working ports, 3/5 exhaust) and are used to control double-acting cylinders. 5/2 is a two-position five-port valve, controlling the cylinder's for […]

What is the purpose of a two-position three-port (3/2) solenoid valve?

A 3/2 solenoid valve has three ports (P inlet, A output, R exhaust) and two positions, and is commonly used to control single-acting cylinders — energised, it supplies air to the cylinder; de-energised […]

What does a two-position two-port (2/2) solenoid valve mean?

“Two-position” means the valve spool has two working positions (open/closed), ”two-port” means it has two fluid connections […]

What is a solenoid valve? What is its basic operating principle?

A solenoid valve is an automated actuator that uses electromagnetic force to drive the valve spool, thereby opening/closing or switching fluid passages. When energised, the coil generates a magnetic field that pushes the moving core (armature […]

Online customer service
Online customer service Scan or click to contact directly
Contacts
Miss Chen(Safety barriers, isolators, surge protectors)
Ms Chen Personal WeChat QR Code

Scan WeChat QR code to add personal WeChat

QQ:2501529964

Phone:17717626508

Email:chenjing@qishan-sh.com

Miss Lu(Field Instruments, Valve Accessories, Terminal Blocks)
Ms Lu Personal WeChat QR Code

Scan WeChat QR code to add personal WeChat

QQ:1695457483

Phone:13636420802

Email:lhm@qishan-sh.com

Mr. Ye(Technical Support, After-Sales Service)

QQ:97010638

Phone:15800474322

Email:web@qishan-sh.com

Online Message

Please fill in the name

Please fill in a valid contact phone number (7-20 digits)

Please enter a valid email address

Please enter the requirement description (at least 10 characters)